Statistical analysisThe absorbance was measured using a microplate reader (VERSAmax; Molecular Devices, San Jose, CA, USA) at an excitation wavelength of 530–560 nm. The value for non-specific absorption at 600 nm was subtracted. $199. New and used Molecular Devices VersaMax's for sale on LabX. Expand the Port (COM & LPT) Right click on the USB Serial Port (COMx) and select Properties. 747. Data were normalized to those of the PBS exposure control group. and California) Tunable Microplate Reader 100-240V ~ 4A 50-60 HZ T4. For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. Concentration was determined by BCA Protein Assay Kit (ref. Data were analyzed with GraphPad Prism. We would like to show you a description here but the site won’t allow us. 2. After incubation, the absorbance of the plate was measured at 450 nm using a microplate reader (VERSAmax™, Molecular Devices Corp. This manual is subject to change without notice. VersaMax Microplate Reader (Molecular Devices cat. The absorbance was assumed to be 100% for the control group. Glossary of Terms. Select Start>Control panel>Device Manager. SpectraMax Plus384, 190, 340PC384, and VersaMax Installation Guide Author: Molecular Devices Subject: Installation Guide Keywords: SpectraMax Versa and others Detection Platform Created Date: 5/17/2023 2:14:27 PMThis version is compatible with the following instruments: SpectraMax® Mini Multi-Mode Microplate Reader (software version 7. +81-3-5282-5261 SpectraMax and VersaMax Plate Readers OperatorÕs Manual Ñ 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Plates values were acquired using a fluorescence microplate reader (570 nm; Versamax, Molecular Devices, San Jose, CA, United States). The in vitro differentiation of BMDMs. All experiments were repeated three times. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. Statistical analysis Graphs and statistics were prepared in GraphPad Prism, version 7. Negative (phosphate buffered saline) (Gibco Waltham, MA, USA) and positive controls. Shop on LabX Shop by Category Shop by Brand Shop by Application Shop by Reseller Sell on LabX Sell Your Equipment Advertise with LabX My AccountMolecular Devices Absorbance Microplate Reader VersaMax. Bovine serum albumin was used as a reference. An aliquot of the extracts dissolved in DMSO with 80 μL of phosphate buffer (pH 6. Lihat Video. The Molecular Devices VersaMax ELISA Microplate Reader enables precise and accurate detection at. Manufacturer: Molecular Devices Model: VERSA MAX Turnable Microplate reader Further Information Descriptions, data, dimensions and quantities are based on the subjective beliefs of the auctioneer and are created to the best of our knowledge and belief. Molecular Devices Versamax; Molecular Devices Vmax; Molecular Devices Fmax Fluorescence; Packard Fluorocount Fluorescence; Packard Spectracount; Tecan Spectrafluor Plus Multilabel; Perkin Elmer HTS-7000 Plus Multilabel; Skatron Skanstacker 300 Washer; Berthold LB96P Luminescence;Finally, cells were incubated with 1% SDS for 2 h at RT to release the dye from the cells, and the cell proliferation rate was assessed by quantification of the amount of dye released from the cells using a spectrophotometer (VersaMax, Molecular Devices) at the wavelength of 570 nm. Spectrofluorometer (e. End-point IgG titers were established as the mean plus three standard deviations of. Used. 2. No accessories are needed and SoftMax® Pro Software. With its advanced features and user-friendly interface, the VersaMax is the perfect choice for a wide range of research. It was verified that absorbance values were proportional to the amount of a bound peroxidase-labeled antibody. After three times washing, the reaction was colored by substrate 3,3’,5,5’-Tetramethylbenzidine (TMB) (T0440, Sigma), and stopped by 2 N HCl. That's why our team is at your disposal the majority of time. Analytical Technologies Group specializes in the maintenance and repair of Molecular Devices microplate readers, including the SpectraMax® and VersaMax™ absorbance readers. The Molecular Devices VersaMax Absorbance Microplate Reader enables both precise and accurate detection at wavelengths in the visible spectrum without the use of filters, providing consequence-free assay flexibility. SpectraMax Plus384 SpectraMax 190 SpectraMax 340PC384 VersaMax Microplate Spectrophotometer Operator s Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Animals and preparation of tumor model. Absorbance was read on a spectrophotometer (VersaMax, Molecular Devices) with SoftMax Pro GxP v5 software. Used. Monitor reader performance on demand to ensure data quality is not compromised between PM/OQ. Values are presented as the mean ?standard deviation (SD). 23,225, Thermo Fisher Scientific). Select up to two wavelengths. Products : General, Microplate Readers. Offer Ends In: 5 Days 05: 02: 03. Brand: Molecular Devices | Category: Laboratory Equipment | Size: 0. The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. Sale. 6/10 #0120-1330d. A. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. 4 (Molecular Devices cat. Absolute values were attained with a standard curve composed of type I bovine skin collagen solution (0. The VersaMax Microplate Reader is supplied with SoftMax® Pro Data Acquistion & Analysis Software, Molecular Devices' industry leading all-in-one data acquisition and analysis software. ISM Equipment Classification (Group 1, Class A) This equipment is designated as. Results are presented as the geometric mean and are derived from at least three experiments. 00 Add to cart Molecular Devices Microplate Reader Spectramax 384 340PC $ 6,295. MDC instruments including: SpectraMax®, VersaMax. Bimolecular fluorescence complementation (BiFC) systemMolecular Devices Versamax Tunable Microplate Reader is available from The Lab World Group. After treatment with GA3The absorbance was measured with a microplate reader (VERSAmax, Molecular devices, San Jose, CA, USA) at 570 nm according to the manufacturer’s instructions. Molecular devices The VersaMax Absorbance Microplate Reader costs between $5,500 and $6,600. 03 billion doses of. The absorbance was detected at 570 nm with a Microplate Reader (VersaMax, Molecular Devices, Sunnyvale, CA). 635. The emodin thermoreversible PG was. 0. The absorbance was measured at 405 nm using a plate reader (VersaMax, Molecular Devices) (N = 3). absorbance readers. The reaction was started by adding 10 µL of the enzyme solution (properly diluted) to 190 µL of 15 mM ONPG in 0. At All-usermanuals. 0 OD Kinetic Read Time: 9 Second Minimum Interval Temperature Uniformity ±0. spectrophotometer (VERSAmax, Molecular Devices). Quantitative real-time polymerase chain reaction For quantitative real-time polymerase chain reaction (qRT-PCR) analysis, total cellular RNA was extracted from ten zebrafish larvae. Study conductThe amounts of chlorophyll a and chlorophyll b were measured at 664. Windows 10 – 2004/20H2/21H1/21H2. Sterile AB medium and a mixture of Me 2 SO, methanol, and water (ratio v/v 1:1:8) served as negative controls. A. +44-118-944-8000. 3 Methods 1. Measurement of biofilm formation inhibitory activity. BMG Labtech - THERMOstar. 0. The. Regular price $ 0. In this study, we have prepared thermoreversible PG containing emodin with high emodin solubility and the gelation temperature suited to physiological use. Select the Driver tab. Find regional support. 3860 N First Street San Jose,CA 95134 USA +1 408. The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. StakMax Microplate Handling System. The absorbance was then determined by an enzyme-linked immunosorbent assay (ELISA) reader (VERSAmax; Molecular Devices, Sunnyvale, CA) at a wavelength of 405 nm. 0 out of 5 $ 2,999. The system provides automation for up to 50For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. Molecular devices Versa Max. 0 nm full width half maximum. All parts of the SpectraTest ABS1 Validation Plate are warranted for a period of ninety (90) days from the original date of. $1,195. 5 mM was used to make the. Supplier: Molecular Devices. From the Windows Start menu, go to All programs > Molecular Devices > SoftMax Pro x. 1. Monday to Friday 8am - 5pm GMT. 7. VersaMax Absorbance Microplate Reader memungkinkan pemilihan hingga dua panjang gelombang sekaligus untuk deteksi absorbansi dalam. ces at one of the following telephone numbers: 408 747-1700 800 635-5577 U. , Sunnyvale, CA, USA). 99 + $42. Finally, the absorbance at 450 nm was detected by an ELISA reader, VERSAmax (Molecular Devices, San Jose, CA, USA). The percentage of cytotoxicity was calculated using the following formula: cytotoxicity (%) = [1 − (At/As) × 100], where At and As refer to the absorbance of a tested. SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers. Unit price / per . +06-6399-8211 Fax +06-6399-8212 ©2002 Molecular Devices Corporation. 1. Supplier: Molecular Devices. Cell viability was represented by percentage values compared to a control and then used to calculate the number of viable cells. ®ABS2, FL1, and LM1 Validation Plates sent to Molecular Devices for recertification at our ISO 17025 accredited lab are disassembled, cleaned, calibrated, an then returned with a new certificate of calibration. In general terms, plasma was added to a 96-well plate containing the targeted antisera, after rigorous washing steps and conjugation with a secondary detection antisera, and the resultant colorimetric reaction was read by scanning spectrophotometry (VersaMax, Molecular Devices, Sunnyvale, CA). 5°C @ 37°C Well-to. Antioxidant enzyme activityProtein concentration was determined from diluted crude venom and nanoparticle samples (1 mg/mL) in deionized water by BCA™ Protein Assay using a UV/V spectrophotometer (VersaMax, Molecular Devices, CA, USA) at a wavelength of 562 nm. 1 mL. And the VERSAmax reader is robotics-compatible. The. (Seongnam, Korea). 专为科研检测平台量身打造的灵活且强大的小型微孔板读板机(酶标仪),具备终点法和动力学检测模式,标准配置6块滤光片,覆盖蛋白定量、细胞活力、农药残留、ELISA实验等. Cell viability was analyzed using a cell counting kit assay (Dojindo). absorbance readers. Battery Backup Uninterruptible Power Supply (UPS) And Power Conditioner For MDS Sciex Molecular Devices VERSAmax Microplate Reader Quote Request. It provides both rapid and sensitive measurements of a variety of analytes across a wide range of concentrations. Oil red O staining. Biosystems CytoFluor 4000 Multi Well Plate Reader $ 1,995. SoftMax® Pro Software for Windows 10 and 11 is designed to provide the simplicity, flexibility and power required for advanced data analysis. The limit of detection for each assay was 156. 00 USD. , St. 4. Cell proliferation assay MDA-MB-231 cells were seeded at a density. 0A 2 Lines Fused, unplug before ser. +86-21-6887-8820 fax +86-21-6887-8890 Germany Molecular Devices GmbH Tel. S. Cells were treated with 150 μl of DMSO and absorbance was quantified in 540 nm using the microplate spectrophotometer system (VersaMax, Molecular Devices, Sunnyvale, CA, USA). The Molecular Devices SpectraMax XPS has an optical design that is the only multi-channel system that truly mimics a dual-beam spectrophotometer. HT22 cells are derived from hippocampal neuronal HT4 cells. Activity was calculated as picomoles of substrate hydrolyzed per min. The narrowly focused light beam and optical design give you the same high performance with round bottom, flat bottom, or half area well plates. 00 USD. 99 shipping. 3, Molecular Devices). ¨ Molecular Devices is a life-science technology innovator Our integrated hardware and software solutions enable automated workflows—from start to finish—for any research application. 00 Read more Molecular Devices Tunable Microplate Reader VersaMaxMicroplate reader with 450 nm filter, such as VersaMax (Molecular Devices, Sunnyvale, CA). JEG-3 cells were transfected with myc-tagged NDRG1 wild type or deletion mutants at the N- or C- terminal as depicted in Figure 5A. Select Add or Remove Programs system settings. 2 and 648. 0 software (GraphPad). SoftMax® Pro Software is the leading solution for microplate reader control and data analysis, where our exclusive INSIDER members help to ensure it remains the most innovative research tool available. (JC-1) (Molecular Probes), respectively. Access all the resources, tools and information you need to stay productive. 파장 정확도 : < ±0. ¨Molecular Devices is a life-science technology innovator Our integrated hardware and software solutions enable automated workflows—from start to finish—for any research application. The optical density of each well at 490 nm was then measured using a microplate spectrophotometer system (VersaMax; Molecular Devices, Sunnyvale, CA, USA). reader (VersaMax, Molecular Devices, Sunnyvale, CA, USA) at 560 nm with background subtraction at 630 nm, based on which the corresponding cell viability was assessed. The. ) gap between the rear of the instrument and the wall. We would like to show you a description here but the site won’t allow us. 3 Methods 1. ¨We would like to show you a description here but the site won’t allow us. treatments were then examined atλ=570 nm using VersaMax eliSa reader (Molecular devices, llc. 5°C @ 37 °C W. Tris base (100 μL of a 10 mM solution) was added to the wells to solubilize the bound SRB, and absorbance was then read at 515 nm on an automated microplate reader (VERSAmax, Molecular Devices, Sunnyvale, CA, USA). VersaMax™ Tunable Microplate Reader, Molecular Devices. The Molecular Devices VersaMax ELISA Microplate Reader enables precise and accurate detection at wavelengths in the visible spectrum without the use of filters, providing consequence-free assay flexibility. It provides ready-to-run protocols, analysis algorithms, and 21 different curve fit options. 단일 튜브 디스펜싱에서 전체 96 및 384 well 플레이트세척까지 간소화된 Microplate 세척입니다. Table of Contents. Manual for Molecular Devices versamax Laboratory Equipment (47 pages) Specifications: 1379/1379020-versamax. The plates were immediately measured at 405 nm for 6 min using a microtiter plate reader (VersaMax; Molecular Devices, Sunnyvale). For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. This version is compatible with the following instruments: SpectraMax® Mini Multi-Mode Microplate Reader (software version 7. BMG Labtech - THERMOstar. SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers. After incubation for 1 h, the medium was transferred to 96-well plates (SPL Life Sciences) in triplication and absorbance was measured by using the ELISA microplate reader (VersaMax, Molecular Devices, USA) at 490 nm. A. Wavelength Range. 47 shipping. Cells were treated with 150 μl of dimethylsulfoxide (DMSO) and absorbance was quantified at 540 nm using the microplate spectrophotometer system (VersaMax, Molecular Devices, Sunnyvale, CA, USA). This reliable model allows for accurate wavelength detection in visible spectrum without the need for filters. Then, the cultured cells were treated with different. SpectraTest ABS1 Absorbance Validation Plate. SoftMax® Pro, the industry-leading microplate reader software, is included at no additional charge. For validation of the Molecular Devices VersaMax™ Absorbance Microplate Reader for use with the Pyrochrome Assay, data acquisition and analysis were performed with SoftMax ® Pro GxP Software. With a wavelength range from 340 to 850 nm, it is the equivalent to having 510 free filters. VERSAMAX - VersaMax Tunable Microplate Reader - VersaMax Tunable Microplate Reader, Molecular Devices - Each Brand: Molecular Devices $20,893. Molecular Devices Corporation. Ann Arbor, MI, USA). 00. 9. The plate was read at 570 nm using an ELISA reader (VERSAMax, Molecular Devices, VWR, Philadelphia, PA, USA). If you are looking for a comprehensive user guide for SoftMax Pro 7. Note: SoftMax Pro Software version 6 and 7 also include a searchable help file within the software. We would like to show you a description here but the site won’t allow us. together with SpectraMax, VersaMax, VMax, and EMax microplate readers from Molecular Devices, offer a quality assurance screening solution for the detection of melamine contamination in such food products as milk, infant formula, pet food, and confectionery. The absorbance was measured at 570 nm using a microplate reader (VersaMax, Molecular Devices). 72 MB. Designed to provide the simplicity, flexibility and power required for advanced data analysis. The mouse hippocampal neuronal cell line HT22 is frequently used as an in vitro model to investigate the role of hippocampal cholinergic neurons in cognitive functions. Select Start>Control panel>Device Manager. and California VERSAMAX Tunable Microplate Reader 100-240V - 4A 50-60 HZ T4. View the supported Window operating systems for the different versions of the SoftMax Pro software. Plates were read using a microplate reader (VersaMax, Molecular Devices) at 595 nm. After freeze-drying, the. The cells were treated with 15, 25, 30, and 45 nm-particles in order to compare the cytotoxicities of different sized nanoparticles on the treated cells. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. 滤光片型光吸收微孔板读板机(酶标仪),简单易用,性价比高,检测结果精确. This. 9. The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. 00 USD Tecan Infinite F200 Reader Fluorescence Reader w WARRANTY $2,750. Florescence intensity was monitored on a Gemini XPS fluorescence microplate reader (Molecular Devices, Sunnyvale, CA, USA) set for 488 nm excitation and 520 nm emission. The catalytic activity was calculated from the production rate of the hydrolyzed product, p-nitrophenol, by monitoring the absorption (405 nm) at room temperature. Wavelength Accuracy. 0A Sunnyvale, CA Made in USA The Molecular Devices VersaMax ELISA Microplate Reader enables precise and accurate detection at wavelengths in the visible spectrum without the use of filters, providing consequence-free assay flexibility. Dual monochromatic, three modes detection, UV Vis Abs, Fluor, and Lum, cuvette. used. MDC instruments including: SpectraMax®, VersaMax. Select Update Driver. The absorbance was detected at 570 nm with a Microplate Reader (VersaMax, Molecular Devices, Sunnyvale, CA). The Molecular Devices VersaMax Absorbance Microplate Reader enables both precise and accurate detection at wavelengths in the visible spectrum without the use of filters, providing consequence-free assay flexibility. We would like to show you a description here but the site won’t allow us. SoftMax® Pro 7. 1 GxP Software is the latest, most secure software to achieve full FDA 21 CFR Part 11 compliance to ensure data integrity. The lysozyme concentration of a sample was determined using a standard calibration curve made of a series of known lysozyme concentrations. molecular devices | 1311 orleans drive | sunnyvale, cA 94089 usA | email: info@moldev. The optical density (OD) was measured at 570 nm (with a reference at 690 nm) by UV-visible spectrophotometer (VersaMax, Molecular Devices, CA, USA) in triplicates. Global research efforts are focused on understanding the SARS-CoV-2 virus in order to develop potential therapies for COVID-19 including: vaccines. The absorbance value (OD) was measured at 492 nm with a microplate reader (VERSAmax, Molecular Devices, Sunnyvale, CA). No accessories are needed and SoftMax® Pro Software. DMEM medium supplemented with the same volume of kit reagent on an empty well was used as a blank. Molecular Devices Spectramax Plate Reader. 0200-6117. The signal was read on an ELISA plate reader (SpectraMax VersaMax, Molecular Devices, Sunnyvale, CA, USA). VERSA MAX-LUNABLE, MOLECULAR DEVICES, MICROPLATE R. Briefly, 100 μl of cell culture medium was mixed with 100 μl of Griess reagent [equal volumes of 1% (w/v) sulfanilamide in 5% (v/v) phosphoric acid and 0. com ©2010 molecular devices, inc. Microplate assays involved a 96-microplate reader (VERSAmax; Molecular devices, Sunnydale, California, USA) used with flat-bottomed 96-well microplates (NUNC, Sigma Aldrich, UK). Absorbance plate reader (e. The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility offered by monochromator-based systems. The collaborative space brings customers and researchers into the lab to test automated workflows for organoid culturing and screening, with guidance from in-house. DMEM medium supplemented with the same volume of kit reagent on an empty well was used as a blank. The VMax Microplate Reader is capable of reading up to two wavelengths at a time in the visible wavelength spectrum (400nm-750nm), with 4 filter choices included at time of purchase. Using a Spectradrop Micro-Volume Microplate (VersaMax, Molecular Devices, CA, USA), RNA was quantified, and 1 μg of total RNA was treated with DNase I (Thermo Scientific, Waltham, MA, USA) before. After 72-h of incubation, CellTiter 96 Aqueous One Solution was added and cells were incubated for a further 2 h. Molecular Devices VersaMax Tunable Temperature range between 4°C above ambient to 45°C Digital controller and display Sold as-is The Molecular Devices VersaMax. A. If the computer is connected to the Internet: Select Search Automatically for updated driver software. Molecular Devices, LLC. absorbance readers. (VersaMax, Molecular Devices, USA). Fluorescence-activated cell-sorting analysis For analysis of DC surface molecules, 5×10 5 DCs were treated with soluble OVA (20 μg/mL), PLGA NPs (20 μg/mL OVA), PEI-coated PLGA NPs (20 μg/mL OVA), or 1 μg/mL. The mixture was incubate at 37 °C for 30 min, and then the reaction was stopped by the addition of 0. Reverse transcription-quantitative polymerase chain reaction To assess phospholipase C gamma 1 (PLCG1) and phospholi-pase C gamma 2 (PLCG2) mRNA levels in each. 68 $. Monitor reader performance on demand to ensure data quality is not compromised between PM/OQ. Briefly, at 3 h before each of the desired time points, 10 µl of the MTS reagent. 0 out of 5 $ 23,995 $ 22,495. 2. A standard curve, provided by the manufacturer, was generated and the sample concentrations determined by 4-parameter logistic curve. 747. The instrument reads any standard cuvette, microcuvette, test tube or 96- and 384-well standard or UV transparent microplate over a full 190 to 1000. New and used Molecular Devices VersaMax's for sale on LabX. VersaMax,SpectraMax340PC384,190,Plus384MicroplateReadersUserGuide 2 0112-0126B ThisdocumentisprovidedtocustomerswhohavepurchasedMolecularDevicesequipment,software,SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Product Overview VersaMax™ ELISA Microplate Reader Manufacturer Molecular Devices® | Available Worldwide Be the first to review this product Request Pricing Molecular Devices® Manufacturer Website. All cell lines were cultivated for 24 h in 96-well cell culture plates with an initial concentration of 1×10 5 cells/mL. Ten microliters of WST-1 was added to wells following exposure and the plates were incubated for 3 h. DISCLAIMER Molecular Devices Corporation reserves the right to change its products and services at any time to incorporate technological developments. Printed in U. Absorbance was read at 412 nm every minute for 10 min using a VersaMax (Molecular Devices, San Jose, CA) spectrophotometer. Although this manual has been prepared with every precaution to ensure accuracy, Molecular Devices SpectraMax and VersaMax Plate Readers OperatorÕs Manual Ñ 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Proliferation was assessed by bromodeoxyuridine (BrdU) incorporation (Cell Signaling Technologies). 0 OD. Read-out was performed within 30 minutes with a microtiter plate reader at 450 nm (Versamax, Molecular Devices). pdf file (03 Dec 2022) Manufacturer: Molecular Devices; Category of Device: Laboratory Equipment, Measuring Instruments; Document: versamax Operator's Manual, File Type: PDF;Search for used versamax. Molecular Devices VersaMax Microplate Reader Molecular Devices VersaMax Microplate Reader Specifications. Ensure data accuracy of your reader. With optimized reagents, option to operate the. The concentrations of anti-RSV G protein IgG antibodies in the samples were. We would like to show you a description here but the site won’t allow us. Molecular Devices SoftMax Pro 5. 00 Add to cart Molecular Devices Microplate Reader Spectramax 384 340PC $ 6,295. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. 00. For more sample throughput, the system can be easily integrated into a full roboticThe VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. 0A Sunnyvale, CA Made in USA VersaMax price. Cet appareil ISM est confomre à la norme NMB-001 du Canada. Molecular Devices Corporation SpectraTest ABS1 Validation Plate Warranty Molecular Devices Corporation warrants this product against defects in material or workmanship as follows: 1. Conventions Used in this Manual. S. MOLECULAR DEVICES VMAX KINETIC MICROPLATE READER. All. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer. The emodin thermoreversible PG was. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. 5×10 3 cells were seeded in 96-well plates, treated with indicated inhibitors for 48 or 72 hours, analyzed 16 hours after BrdU addition, and absorbance measured at 450nm using a spectrophotometer plate reader (VersaMax, Molecular. The. The PathCheck Sensor is a revolutionary new awardwinning1 technology in SpectraMax® Instruments for measuring the fluid level in every well of a microplate 2–5. Used. Culture medium was removed, and lysis buffer (10 ml) was pipetted into each well. for cell lysis via visual inspection and optical microscopy (VersaMax, Molecular Devices, Sunnyvale, CA, USA) observation and checked by measuring the absorbance at OD680. The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. The absorbance was measured at 490 nm using a VersaMax ELISA reader (Molecular Devices, Sunnyvale, California, United States). Molecular aspects of color variation in luciferase emission have been the subject of numerous studies: various mechanisms have been proposed [6] and multicolor reporter proteins have been created and applied in cell-based. Additionally, the VersaMax Microplate Reader can be seamlessly integrated with the StakMax® Microlate Handling System through the SoftMax Pro Software. Concluding Remarks. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. 8), 40 μL of tyrosinase, and 40 μL of L-DOPA was put in each well. Florescence intensity was monitored on a Gemini XPS fluorescence microplate reader (Molecular Devices, Sunnyvale, CA, USA) set for 488 nm excitation and 520 nm emission. S. Shark chondroitin sulfate A sodium salt (Sigma Aldrich Corp. However, whether these cells exhibit the serotonergic neuronal phenotype observed in mature hippocampal neurons. 2 or higher, standard edition only, no GxP) VersaMax™ Microplate Reader (Serial numbers begining with BNxxxxx and BNRxxxxx are supported) SpectraMax® 190 Absorbance Microplate Reader (Serial. p-nitrophenol (Sigma) with diluted concentrations ranging from 0 to 0. Integrate any SpectraMax Multi-Mode Reader with the StakMax Microplate Handling System from Molecular Devices. Get pricing and purchase lab equipment and instrumentation today. VersaMax ELISA Microplate Reader. Invasion assayCells were seeded into the top chamber of a 96-well matrigel-coated plate with 8-m-pore polyethylene terephthalate membrane inserts (Corning). For wells that were not exposed to dehydration (positive control), all the cells (100%) survived for the 60-min test. Versamax Microplate Reader dibangun di sekitar monokromator kisi. and California) Tunable Microplate Reader 100-240V ~ 4A 50-60 HZ T4. The absorbance was read at 570 nm using a spectrophotometer (VersaMax, Molecular Devices, San Jose, CA, USA). The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. Ann Arbor, MI, USA). Western Blot. E. It also integrates with the powerful SoftMax Pro Software for. The Molecular Devices VersaMax ELISA Microplate Reader enables precise and accurate detection at wavelengths in the visible spectrum without the use of filters, providing. 0 (Molecular Devices, Sunnyvale, CA). , Sunnyvale, CA). It provides both rapid and sensitive measurements of a variety of analytes across a wide range of concentrations. Statistical Analysis. The optical densities (ODs) of the reactants were measured at 450 nm using a microplate spectrophotometer (Versamax, Molecular Devices, CA, USA). Turn the reader on and secure the USB cable. All animal experiments were performed in compliance with the relevant laws and. We would like to show you a description here but the site won’t allow us. 4. At 5 seconds to read a 96-well endpoint assay or a 5 second minimum interval between kinetic reads, the VMax Microplate Reader has both speed and performance. Absorbance was measured with a microplate reader (VERSAmax Molecular Devices Corporation, Sunnyvale, CA, USA) at 570 nm to assess cell viability. For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747. Filterless Absorbance Microplate Readers provides fast & consistent results with steady temperature enabling a wide range of assays - ELISA reader, microbial. For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. StakMax. This robust model allows precise wavelength detection in. 5 million deaths worldwide have been caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (), along with high levels of unemployment and far-reaching supply chain issues in the world’s economy. 00 USDLocation: Hampton, New Hampshire, United States Member Since: 28th February, 2012 (12 years ago) Current Listings: 3982 Return Policy: WE OFFER 180 DAY WARRANTY ON ALL ITEMS. Open the Windows Task Manager, go to the Services tab, and click Open Services. Furnace Manuals. 5% NP-40) supplemented with protease and phosphatase inhibitor cocktail (GenDepot, Baker, TX, USA). SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer. The Organoid Innovation Center at Molecular Devices combines cutting-edge technologies with novel research methods to address key challenges of scaling complex 3D biological models. 003 OD ±1.